Products

page_banner

DOA Test Device drug Fentanyl FYL Urine Rapid Test Kit

A rapid, one step test for the qualitative detection of Fentanyl in human urine. For professional in vitro diagnostic use only.


Sample type:

    Product Advantage:

    • High Detection accuracy
    • High cost performance
    • Quality assurance
    • Fast delivery

    Detailed Description

    The One Step Fentanyl Test Device is a lateral flow chromatographic inmunoassay for the detection of Fentanyl in human urine at a cut-off concentration of 200 ng/mL.

    This assay provides only a qualitative, preliminary analytical test result. A more specific alternate chemical method must be used in order to obtain a confirmed analytical result. Gas chromatography/mass spectrometry (GC/MS) or Liquid Chromatography/mass spectrometry (LC/MS) are the preferred confirmatory methods.  Clinical consideration and professional judgment should be applied to any drug of abuse test result, particularly when preliminary positive results are used.

    Specimen: Urine

    Product Format: Strip/Cassette/Dipcard/Uncut Sheet

    Specification: Strips:100Tests/Box; Cassette: 40Tests/Box

    Materials Provided:

    1. Test device

    2. Desiccants

    3. Package insert

    4. Disposable specimen droppers (for test cassette only)

    adv_img

    Directions for Use

    Allow the test device, and urine specimen to come to room temperature [15-30℃ (59-86℉)] prior to testing.

    [For Strip]

    1) Remove the strip from the foil wrapper or the desiccated container (bring the container to the room temperature before opening to avoid condensation of moisture in container). Label the strip with patient or control identifications.

    2) Immerse the strip into the urine with the arrow end pointing toward the urine. Do not cover the urine over the MAX (maximum) line. You may leave the strip in the urine or you may take the strip out after the urine nearly arriving at the top of the test window of the strip and lay the strip flatly on a non-absorptive clean surface.

    3) Read results at 5 minutes.

    DO NOT INTERPRET RESULT AFTER 10 MINUTES.

    sdf

    [For Cassette]

    1) Remove the test device from its foil wrapper by tearing along the slice (bring the container to the room temperature before opening to avoid condensation of moisture in container). Label the device with patient or control identifications.

    2) Using the specimen dropper, withdraw the urine sample from the specimen cup and slowly dispense 3 drops (approximately 120μl) into the circular sample well, being careful not to overfill the absorbent pad.

    3) Read results at 5 minutes.

    DO NOT INTERPRET RESULT AFTER 10 MINUTES.

    图片 2

    [For Dipcard]

    1) Remove the test device from the foil pouch.

    2) Remove the cap from the test device. Label the device with patient or control identifications.

    3) Immerse the absorbent tip into the urine sample until the urine nearly arriving the top of the test windows of the dipcard. Urine sample should not touch the plastic device.

    4) Replace the cap over the absorbent tip and lay the device flatly on a non-absorptive clean surface.

    5) Read results at 5 minutes.

    DO NOT INTERPRET RESULT AFTER 10 MINUTES.